Workspace Management

How much office space do you need per person?

The quick answer is about 10 m², or 100 sq ft, per person. In a hybrid office that number is only half the sum. The other half is how many people are in on your busiest day.

The DuoMe team ·

A bright hybrid office from above, with rows of shared desks, phone booths along the wall and a lounge area by the kitchen

The quick answer is about 10 m², or roughly 100 sq ft, per person for a typical UK office. That covers the desk and a share of everything around it: walkways, meeting rooms, kitchens and breakout space.

In a hybrid office, that number is only half the sum. The other half is how many people you are sizing for. Multiply by headcount and you pay for desks that sit empty most of the week. Multiply by the average day and Tuesday doesn’t fit.

This guide shows the method we use: start from people, find your busiest day, turn that into desks, then turn desks into space. The calculator below does each step with your own numbers.

The quick answer: UK benchmarks

These are the figures most UK space plans start from.

Benchmark Figure Source
General office workspace 10 m² per person British Council for Offices, 2023
All-in space per workstation About 100 sq ft (9.3 m²) Lambert Smith Hampton, Total Office Cost Survey
Legal minimum 11 m³ per person HSE

The BCO and LSH figures are measured as net internal area (NIA), the area UK office rents are quoted on. They include circulation and shared space, not just the footprint of a desk. The HSE figure is a volume, and a furnished office needs far more than it.

Why headcount is the wrong starting point

Benchmarks were written for offices where everyone came in every day. Most UK offices no longer work like that.

The British Council for Offices found UK offices are 30% occupied across the working week, and 40% from Tuesday to Thursday. If you give every person a desk at 10 m² each, most of that space is empty on most days. For more of the data, see our UK hybrid working statistics.

So the per-person figure still holds, but “person” should mean a person in the office on your busiest day.

Work it out with your own numbers

Change any number and the answer updates. The figures filled in are our worked example: 140 people today, growing 15% by move-in, coming in three days a week.

Your team
%
3

Your policy or your best guess. Part-timers count as people, not FTE.

Assigned desks are never shared, so each one counts as a whole desk.

% of people

Don't know it? DuoMe shows your busiest and quietest days from real bookings. Leave blank to use the model.

Your space
sq ft
Change the assumptions
%

Presence allows for leave and sickness. The busiest-day factor is busiest day ÷ average day, typically 1.1–1.25.

m²
% of NIA
m²
£/sq ft

Desks for a busy week

110desksTypical busiest day: 99

161 people at move-in, about 62% in on the busiest day. 110 desks cover it in about 19 weeks out of 20. A typical week needs 99.

Plan for

From headcount to desks

Space by use

Net internal area (NIA), the area UK rents are quoted on.

Meeting rooms

10 rooms

Desks at 1 to 5 office days

Same method for every bar. Your setting is in red.

Your busiest day, not your average day

Three things decide how many people are in on your busiest day.

  1. Office days a week. At three days a week, the average day has 60% of people in.
  2. Leave and sickness. Not everyone can come in even on their office days. Statutory leave of 5.6 weeks is about 11% of working days, so we assume about 88% of people could be in.
  3. Clustering. Left to choose, people pick the same days. Badge data from Kastle puts the peak Tuesday at about 1.17 times the weekly average.

Put together, 161 people at three days a week gives about 85 people on an average day and about 99 on a typical busiest day. In a busy week, the kind you get about one week in twenty, it reaches 110.

Size for the busy week. A typical week leaves no room for the week everyone comes in for the same all-hands.

From desks to square feet

Once you know how many desks you need, add the space around them.

  • Workstations. About 6.5 m² per desk for the desk, chair and the space to get in and out.
  • Meeting rooms. About one room for every 12 desks, at around 18 m² each. Hybrid meetings need more small rooms than big ones.
  • Circulation and amenity. Walkways, kitchens, breakout and storage. Plan for about 30% of the total.

Worked example: 110 desks need 715 m² of workstations and 10 meeting rooms of 180 m². Circulation and amenity take the total to about 1,280 m², or 13,800 sq ft. That is about 11.6 m² per desk, in line with the BCO and LSH benchmarks once you count meeting rooms.

Desk-sharing ratios in practice

A desk-sharing ratio is people per desk. In our example, 161 people share 110 desks, a ratio of about 1.46 to 1.

The ratio follows from how often people come in. With the same method, 161 people need:

Office days a week Desks Space People per desk
1 42 About 5,300 sq ft 3.8
2 77 About 9,600 sq ft 2.1
3 110 About 13,800 sq ft 1.5
4 141 About 17,400 sq ft 1.1
5 148 About 18,400 sq ft 1.1

Even at five days a week you don’t need a desk for every person, because someone is always on leave or out at a client.

Assigned desks change the sum. Anyone who needs their own desk every day takes a whole desk out of the shared pool, so add them on top.

Lower your busiest day before you sign

The cheapest square foot is the one you don’t need. If you set team days and spread teams across the week, the busiest day comes down.

In our example, spreading six teams’ days across Monday to Friday brings the busiest day from 110 to 92 people. That is 18 fewer desks, two fewer meeting rooms and about 2,350 sq ft less space before you have looked at a building.

You can try it with your own teams in the busiest-day planner. If you are planning a move, our guide on how to plan an office move walks through every step. If you are cutting space where you are, see downsizing your office for hybrid working.

Measure before you decide

Every figure above is a model. The best number is your own busiest day, measured over a few months before you commit to a lease.

If you know it, put it in the calculator under “Measured busiest day” and it will use it in place of the model. DuoMe shows your busiest and quietest days from real desk bookings, so the next plan starts from your numbers.

Frequently asked questions

How many square feet per person for an office?

About 100 sq ft (9.3 m²) per workstation is a common UK all-in figure, and the BCO recommends 10 m² per person for general workspace. In a hybrid office, apply it to the people in on your busiest day, not your total headcount.

What is the minimum office space per person in the UK?

The HSE sets 11 cubic metres per person in a workroom, counting ceilings up to 3 metres. That is a legal floor, not a planning figure. A furnished office with desks and walkways needs far more.

How many desks do I need for a hybrid team?

Enough for your busiest day in a busy week, plus any assigned desks. For 161 people at three office days a week, that is about 110 desks. Spreading team days across the week can bring it to about 92.

What is a good desk-sharing ratio?

It depends on how often people come in. At three days a week, about 1.5 people per desk is typical. Check yours against your busiest day, not your average, or Tuesdays will run out of desks.

Related articles

Workspace Management

Downsizing your office for hybrid working

Most hybrid offices pay for desks that sit empty. But cut to the average day and Tuesday doesn't fit. Here is how to downsize safely, with a cost calculator for your own numbers.

See your floor in DuoMe.

Book a demo