Office space calculator · UK
How many desks and how much space do you need?
Size your next office on your busiest day, not your average one. Change any number and the answer updates.
Desks for a busy week
110desksTypical busiest day: 99
161 people at move-in, about 62% in on the busiest day. 110 desks cover it in about 19 weeks out of 20. A typical week needs 99.
From headcount to desks
Space by use
Net internal area (NIA), the area UK rents are quoted on.
Meeting rooms
10 rooms
Desks at 1 to 5 office days
Same method for every bar. Your setting is in red.
Next step
Next: check the busiest day.
Will your busiest day fit?
Your peak depends on which days people come in. Plan team days and see if your busiest day fits.
Plan team daysWhat will this office cost?
Rent is only part of it. Add rates, service charge and fit-out for an all-in cost per desk.
Cost per deskMeasure your real busiest day
DuoMe shows your busiest and quietest days from real bookings, so the next plan starts from your numbers.
Attendance in DuoMeMethod
How it works
The method in plain words
The average day doesn't size an office; the busiest day does. We take the share of people in on an average day (office days ÷ 5, less leave and sickness), lift it by the busiest-day factor, and add a buffer for chance. "Busy week" covers the busiest day in about 19 weeks out of 20. "Typical busiest day" is the middle of the range. Assigned desks are added one for one.
For the method with a worked example, read how much office space you need per person.
Remit Consulting's UK office occupancy of 44% (late Jan 2026) is an average across offices, not a peak day. Your busiest day will run higher.
Every default and where it comes from
- 140 people, 15% growth. Example values. 33% of UK occupiers plan to expand (Irwin Mitchell Office Occupiers Survey 2026, accessed Oct 2026).
- 3 office days. The most common minimum, set by 48% of employers with one (CIPD Flexible working 2025, accessed Oct 2026).
- 88% presence. 5.6 weeks' statutory leave is about 11% of working days (gov.uk, accessed Oct 2026), plus about 1–2% sickness. Estimate.
- Busiest-day factor 1.17. From US data: Kastle's 2026 barometer puts its peak Tuesday at 1.17 times its weekly average (Tuesday 62.6%, Friday 34.0%; Kastle Systems, accessed Oct 2026). UK offices are also busiest Tuesday to Thursday (Cluttons Q1 2026, accessed Oct 2026). Typically 1.1–1.25. The busiest-day planner uses the same factor, so both give the same busiest day.
- Busy-week buffer. Treats each person's day as independent, then covers the busiest day in about 19 weeks out of 20. Teams and friends tend to come in together, so real peaks can run higher.
- 6.5 m² workstation area per desk. Assumption, including the walkway between desks. The result is compared with 100 sq ft (9.3 m²) NIA per workstation (LSH Total Office Cost Survey, data June 2025, accessed Oct 2026) and 10 m² per person (BCO Guide to Specification 2023, accessed Oct 2026).
- 30% circulation and amenity. A share of total NIA, not an uplift: corridors, reception, kitchen and breakout. LSH's model uses about 20% circulation plus 15% amenity. Assumption.
- 1 meeting room per 12 desks, 18 m² each. Rule of thumb (an 8-person room is about 18–20 m²). 29% of organisations are adding small meeting rooms (JLL Occupancy Benchmark 2026, accessed Oct 2026).
- People per desk. JLL 2026 puts average seat sharing at 1.2 people per desk in EMEA (1.3 global). Global, not UK-specific.
- Rents. Grade A mid-points from Oktra, Cost of UK office space (accessed Oct 2026; Oktra updates quarterly). Base rent only: rates, service charge and fit-out are in the office cost calculator.
- Units. 1 m² = 10.764 sq ft. Space is sized on move-in headcount; "space you hold today" compares with today's office.
Bring this desk count to a demo.
We'll show the new floor set up in DuoMe, with desks, rooms and team days.